Contact Us | Print Page
Table 1. Summary - Formed Finishes Specification Requirements

 

F6
Surface of high importance. Alignment, appearance very important

F5
Structural surfaces of importance. Frequent close scrutiny

F4
Structural surfaces of importance observed frequently

F3
Exposed surfaces not subjected to close scrutiny

F2
Keying surfaces for plaster and other thick coatings

F1
Roughness permitted: fill tie holes, defects. Colour variation permitted.

Architectural or feature panels. High velocity water channels

Walls, panels, columns, beams, piers, soffits, parapets, railings, offices, foyers, public areas

Walls, panels, columns in secondary areas (e.g. basements, car parks)

Building and engineering structures viewed from afar

Interior and exterior surfaces to be coated

Concealed surfaces. Foundations, lined walls, upstream dam surfaces

Surface plane variation

Sample reference panels required

R

R

R

 

 

 

Abrupt (mm)

6

 

Abrupt at Construction Joints (mm)

1

2

4

6

 

Abrupt at Joints of Shutters (mm)

0.5

1

2

3

 

Gradual (mm)

4

6

6

6

6

Colour

Discolouration

P

P

P

 

 

 

Contamination

P

P

P

 

 

 

Dusting

P

P

P

P

P

 

Retardation

P

P

P

 

 

 

Efflorescence

P

P

P

P

P

 

Acceptable shade range

*

*

*

 

 

 

Physical Irregularities






Blowhole limits

2

3

4

5

7

7

Formwork deflection

2mm

1 / 360

3mm

1 /270

3mm

1 /270

 

 

 

Grout loss / scour

E

P

P

P

 

 

Form tie

A

A

A

 

 

 

Sheet location

A

A

A

 

 

 

Scabbling

P

P

P

P

 

 

Chipping

P

P

P

P

 

 

Spalling

P

P

P

P

 

 

Surface dressings

Filling composition

S

A

S

 

 

 

Method

A

A

A

A

 

 

Action

A

 

 

 

 

 

R=Required   S=Specifier to stipulate   P=Precautions to minimise effects   E=Prevent occurrence  A=Approval required